SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Journal of Renin-Angiotensin-Aldosterone System
This Article
Right arrow Free Full Text (Free PDF) Free
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Peters, S.
Right arrow Articles by Richter, C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peters, S.
Right arrow Articles by Richter, C.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

First-in-man use of polymer-free valsartan-eluting stents in small coronary vessels: a comparison to polymer-free rapamycin (2%)-eluting stents

Stefan Peters

Klinikum gGmbH Quedlinburg, Cardiology, Germany, ste.peters{at}asklepios.com

Boris Behnisch

Translumina GmbH, Hechingen, Germany

Torsten Heilmann

Translumina GmbH, Hechingen, Germany

Christian Richter

Translumina GmbH, Hechingen, Germany

Introduction. Orally administered angiotensin receptor antagonists administered after bare-metal stent implantation and even after drug-eluting stent implantation seem to lower in-stent restenosis rates.Whether valsartan-eluting stents are similarly effective was tested here in a first-in-man trial.

Materials and methods. The efficacy of a polymer-free drug-eluting stent coated with 300 mcg valsartan was compared to a coating with a 2% rapamycin solution in small (≤ 2.5 mm) coronary vessels with and without oral valsartan on the basis of the YUKON Choice stent system (Translumina GmbH, Hechingen, Germany). Fifteen patients (eight males, mean age 64.4±7.7 years) were treated with YUKON Choice valsartan-eluting stents and 30 patients (24 males, mean age 65.7±8.4 years) received YUKON Choice rapamycin-eluting stents. Clopidogrel was given for six months in all patients.

Results. Within the first 30 days, no adverse events occurred in either group. Binary in-stent restenosis rate was 30.8% (four in 13 angiographic controls) in the valsartan-eluting stent group and 35.0% (eight in 20 angiographic controls) in the rapamycin-eluting YUKON Choice stent group. Mean late lumen loss was 0.78±0.53 mm and 0.79±0.58 mm, respectively. Target lesion and target vessel revascularisation rate was 26.6% and 25.0%, respectively. No restenoses in rapamycin-eluting YUKON Choice stents appeared in 12 patients with adjunct oral valsartan administration.

Conclusions. If polymer-free YUKON Choice stents are used in small vessels, valsartan-eluting stents show an identical efficacy as rapamycin-loaded stents. In patients with rapamycin-eluting YUKON Choice stents it seems that the efficacy can be increased by oral valsartan administration.

Key Words: drug-eluting stents • in-stent restenosis • polymer-free stent design • valsartan

Journal of Renin-Angiotensin-Aldosterone System, Vol. 10, No. 2, 91-95 (2009)